**                 ***************** README *****************                **
*******************************************************************************

The files contained in the HP Advanced Server Management Package for VMware
ESX Server provide the user with multiple system management. The 
standard configuration would be to use the HP Systems Insight Manager (HP SIM)
software. For more information on HP SIM, see:  

http://h18013.www1.hp.com/products/servers/management/hpsim/index.html

KNOWN ISSUES:
============================================================================
The link to storage controllers that do not have any disk drives attached 
might not be displayed in the System Management Homepage.


The HP Management Agents retrieve the Processor Utilization information for 
only Processor 0, even on a multi-processor system. 


The status for the DVD/CD devices is shown as Unknown in the System 
Management Homepage on some HP ProLiant Systems.


The help pages for Rack Asset, Server Enclosure and Power Enclosure is not 
displayed when launched from the System Management Homepage.


Information related to the 4 GB Qlogic mezzanine HBA on hp ProLiant c-Class 
blade servers is not displayed in the System Management Homepage.


INSTALLATION INSTRUCTIONS:
============================================================================

Note that you must always be logged on as username "root" for all of the
instructions in this document.

Once the VMware ESX Server system has been installed and configured, log onto 
the console operating system. Change the working directory to the directory 
where this file was unbundled (e.g. /home/vmware/hpmgmt). The installation 
script will perform some basic checks and will guide you through the 
installation process.

On ESX 2.5.x:
-------------
In order to see VMware SNMP information you must enable the VMware SNMP sub-
agent. If the sub-agent is disabled, you may enable it in the SNMP
Configuration area under the Options tab in the MUI or by answering 'y' 
when prompted by the installation script. 

On ESX 3.0.x:
-------------
You must enable the firewall port for the `hpim' service (2381) for accessing 
the System Management Homepage. The `snmpd' service should be enabled in the 
firewall for the Insight Manager agents to communicate properly with the hp 
Systems Insight Manager. These ports can be enabled by using the 
"esxcfg-firewall" command in the service console, or by answering 'y' when 
prompted by the installation script.

For the SIM certificate to be added in SMH, the outgoing connections on port 
280 needs to be enabled in the firewall. This connection can be opened by using 
the command "esxcfg-firewall -0 280,tcp,out,sim-cert" in the service console, 
or by answering 'y' when prompted by the install script.


Some things you will want to consider before you start the installation:

1.  Will you be using the HP SIM console? If so, you want to 
    allocate an IP address for the HP SIM console as you will
    need to provide it during the installation process. You must provide
    either the IP address or the fully qualified DNS name for the HP SIM
    console. This will be an additional "rocommunity" string in the 
    snmpd.conf file. The installation script will ask for this information
    or you can skip this step and modify "/etc/snmp/snmpd.conf" to the
    necessary information.

2.  Do you have other ProLiant or HP servers that you wish to manage? If
    so, you should layout what the SNMP community strings should be. The
    default is usually "public" but since everybody knows the default, this
    is not considered to be very secure. The snmpd.conf(5) man page has
    more information. In general, you need to know the "community strings"
    (e.g. public) and the IP address of the HP SIM console.

Once you have the information to configure the SNMP and web enabled agent
interfaces, you can install the packages. To install, you must be logged
onto the console OS as user name "root". At the command prompt:

[root@myserver hpmgmt] ./installvm760.sh

You will be presented with the various installation options.


Automating the Installation:

To automate the installation of the agents, make a copy of the 
hpmgmt.conf.example file and rename it to hpmgmt.conf. This file contains
the configuration information for the hpasm package, vmware-snmp sub-
agent (for ESX 2.5.x) and firewall port configurations (for ESX 3.0.x). Edit 
this file to fit your environment. Please see the example
file for complete details on the configuration settings. At a minimum, 
you should configure Local Read/Write community for snmp and the vmware snmp
subagent. When you are ready to install, run the script as follows:

[root@myserver hpmgmt] ./installvm760.sh --silent --inputfile hpmgmt.conf

This will start the installation process immediately--you will not be
prompted for confirmation. If you are missing information from your
configuration file, you may be prompted for it during installation.

To automate the configuration of the System Management Homepage, place
a copy of the smhpd.xml file with the desired settings into the same 
directory as the installvm760.sh script. When performing a silent install
this file will be copied to the appropriate directory. It is recommended
to use a file from a pre-existing installation rather than edit by hand.


VALIDATING INSTALLATION: 
============================================================================

You can run a few utilities to validate that the installation of the
package was successful.

snmpwalk localhost public enterprises | grep hp
       This command will list all the SNMP Management Information Block (MIB)
       items associated with "hp". These are the HP management items.


snmpwalk localhost public enterprises | grep 6876
       This command will list all the SNMP Management Information Block (MIB)
       items associated with the VMware ESX Server software. These are the 
       VMware management items. Note that once the system is rebooted, this
       command may no longer work if you have not enabled the VMware SNMP
       subagent to run at startup (automatic). If you want full monitoring
       of the system, you need to log onto the VMware console as previously
       described and enable automatic start of the VMware SNMP processes.

https://fully.qualified.name.com:2381
       Point your web browser to the fully qualified name of this server (or
       the IP address) and port 2381. Note that you MUST use the "https://"
       prefix and port ":2381" or this will not work. This will allow you
       to log into the Web Agent and view the status of the machine. The
       System Management Homepage uses OS accounts for authentication.


REMOVAL INSTRUCTIONS:
============================================================================

You need to change to the directory where this file is located. Then enter
the following command:

     ./installvm760.sh --uninstall 

This will remove all instances of the HP Advanced Management Software 
including the snmp stack (the snmp stack will not be removed on ESX 2.5.3 
and above). If you wish to continue monitoring your VMware installation 
through SNMP without the HP ProLiant Advanced Server Management software, 
you will need to re-install the SNMP packages from the VMware media. The 
VMware SNMP packages are located on the VMware media at:

     ./VMware/RPMS/ucd-snmp-{version}.i386.rpm
     ./VMware/RPMS/ucd-snmp-utils-{version}.i386.rpm

On ESX 3.0.x, the firewall port for the `hpim' service and port 280 (used by 
hp SIM) will be disabled during uninstall of the agents. The `snmpd' service 
can be disabled in the firewall by using the command "esxcfg-firewall 
--disableservice snmpd".


AGENT CONFIGURATION:
============================================================================

For complete details on configuring HP Insight Manager Agents, please see the
hpasm man page.


Support for 4GB Qlogic and Emulex HBAs has been added with this version of the 
agents for ESX 3.0.x. For the storage agents to display the correct information
for the Qlogic and Emulex HBAs, the libraries corresponding to the Qlogic and 
Emulex driver versions have to be installed on the ESX 3.0.x Service Console. 
Please ensure that you run through these instructions ONLY if you do not see a 
link for either the HBA or the target drives in the System Management Homepage.

The following steps guide you through the installation for the corresponding 
libraries -
1. Download the libraries for the driver loaded in the vmkernel from the 
following links:
	Link for Emulex libraries - http://www.emulex.com/ts/docoem/vmware/index.html
	Link for Qlogic libraries - http://support.qlogic.com/support/oem_product_detail_vmware.asp
2. Stop the 'hpsmhd' and 'hpasm' agents by issuing the commands, 
'service hpsmhd stop' and 'service hpasm stop' from the service console 
(you must be logged in as root).
3. Remove the older corresponding libraries from the '/opt/compaq/storage/bin' 
directory. ('libdfc.so' for Emulex, and 'libqlsdm.so' for Qlogic).
4. Install the libraries which were downloaded in step 1 using the install 
script present in those packages.
5. For the Qlogic libraries you might have to rename the library file. Use the 
following command to rename the library file - 
	'mv /usr/lib/libqlsdm-ia32.so /usr/lib/libqlsdm.so'
5. Restart the 'hpsmhd' service first using the command 'service hpsmhd start'.
Then, start the 'hpasm' service using the command 'service hpasm start'.



ACKNOWLEDGEMENTS:
============================================================================

This package contains additional 3rd-party software. By installing this
software you agree to the licensing terms for use of this software set forth
in the LICENSE file.


Copyright (c) 2005, 2006  Hewlett-Packard  Development  Company, L.P.